Keywords :MOTOR PARTS,JINZEN GUN & PARTS,PULLER ATTACHMENT,MOTOR PARTS

KNIFE
Current location: Home»JINZEN News » Latest News » Common fault inspection machine and the solutions

Recommended Products

JINZEN BOBBIN CASE JZ-10301 BC-31-15
JINZEN BOBBIN CASE JZ-10301 BC-31-15
Place of Origin: Zhejiang, China (Mainland)
Brand Name: JINZEN
Use: Industrial
JINZEN Sewing machine connection rod with item No. MD04
JINZEN Sewing machine connection rod with item No. MD04
FOB Price: Get Latest Price
Min.Order Quantity: 50 Piece/Pieces
Supply Ability: 20000 Piece/Pieces per Month
Port: ningbo shanghai
Payment Terms: L/C,T/T
JINZEN stainless steel sewing scissor and shear with size 8' 9' 10' 11'12'
JINZEN stainless steel sewing scissor and shear with size 8' 9' 10' 11'12'
FOB Price: Get Latest Price
Min.Order Quantity: 100 Piece/Pieces
Supply Ability: 5000 Piece/Pieces per Month
Port: ningbo
Payment Terms: T/T
JINZEN HOOKS JZ-10007 HSH-7.94A
JINZEN HOOKS JZ-10007 HSH-7.94A
FOB Price: Get Latest Price
Supply Ability: 15000 Piece/Pieces per Month
Port: NINGBO SHAIHANG
Payment Terms: L/C,T/T
JINZEN Presser Foot WITH WHEEL
JINZEN  Presser Foot WITH WHEEL
FOB Price: Get Latest Price
Min.Order Quantity: 100 Piece/Pieces
Supply Ability: 20000 Piece/Pieces per Month
Port: ningbo shanghai
Payment Terms: L/C,T/T

Top articles

Latest articles

Your browsing history

    Loading...

Common fault inspection machine and the solutions

Categories: Latest NewsStars: 3Stars Visit: - Release time: 2015-04-02 10:49:00
Font size:【 Large Middle Small Source: Editor: Author:
Maintenance of cloth inspecting machine, first of all need to drive part of the equipment in all driving gear, sprocket and conduct regular inspections and timely maintenance to ensure the test gas, transmission machine parts can keep good lubrication condition. In addition, in the periodic inspection, if found to have serious wear parts should be replaced in a timely manner. Secondly, we need to promptly remove cloth inspecting machine motor, drive part of the dust, hair pieces of cloth. Finally, in the course of daily use, we should often clean cloth inspection machine and inspection, fluorescent tube light dust cloth glass cloth hair debris, which can effectively ensure the cloth inspecting machine standard lighting.
 
Cloth inspecting machine common fault of the following phenomena:
 
The takedown is uneven
 
The cloth is irregular due to the cloth roller and guide roller is not parallel to the roller, so adjust and guide roller parallelism can completely eliminate the uneven problem of cloth.
 
Fabric tilt, in cloth inspecting machine. When "killed".
 
This is mainly because the fabric guide roller cloth inspection machine is not parallel to the equipment operating personnel, as long as the adjustment of the parallelism of the guide roller can be solved. Fabric guide roller or roller rotates a circle will be part of stagnation phenomenon
 
This phenomenon is mainly because of the replacement of bearings and accessories with good, cloth guide roller and roller axle bending caused by damage, can be adjusted with good equipment spare parts, and then bending deflection of shaft to solve the correction. Fault 6 cloth inspecting table glass plate illumination brightness is not enough: cloth inspecting table glass plate illumination brightness is mainly because of the fluorescent lamp and the inspection glass cloth on the falling dust cloth, hair debris, or lamp voltage instability caused, as long as the regular removal of dust, fluorescent lamp, cloth inspection TGI glass plate the cloth hair debris, and the stability of the lighting voltage can easily solve this problem.
 
Complex code device length is not accurate
 
In the process of conveying the material, cause less friction, wear long round of long-term use or operation may cause disruption, cloth inspecting machine complex code device length accuracy problem, we can improve the relative temperature distribution to increase the movement friction, cloth for comptroller, often clean the dust. The long wheel and oil and other methods to solve.
 
Cloth inspecting machine, heavy fabric cloth
 
The cause of the problem may be the moving parts of the machine, dust and oil Bumau, or transmission components are not installed, as long as we correct installation of cloth inspecting machine transmission parts, and regularly clean up the oil inside the machine, cloth coat can be.
 
The noise of the machine is large
 
Test needle machine big noise is due to poor lubrication, the machine parts wear or screw loosening, and some with the drive shaft wear caused a large gap, resulting from moving around, we can through the regular equipment with lubricating oil, the correct installation of various components, modify or replace damaged or substandard parts to solve this problem.
 
Other operation fault
 
Long term lubricating oil will cause equipment other malfunctions during operation, only need to regularly for equipment lubricating oil.